Measuring moisture content (2024)

Measuring moisture content

Measuring moisture content (1)

Moisture content is simple in theory – but in reality, it's almost impossible to obtain an accurate, repeatable MC measurement. Here’s why.

Water activity, which provides information about product safety and quality, is often thought to be a more complicated measurement than moisture content. But making accurate, repeatable moisture content measurements is not as simple as it seems.

In theory, moisture content (MC) measurement is easy. Simply determine the amount of water in a product, and compare that to the weight of everything else in the product. In fact, it can be a difficult and complex process to obtain an accurate percentage of water in a product.

Here’s why.

Moisture in food is reported on a wet basis or a dry basis

These different reporting methods can cause confusion. For the wet basis, the amount of water is divided by the total weight of the sample (solids plus moisture). For the dry basis, the amount of water is divided by the dry weight (solids only).

Unfortunately, moisture content is often reported only as a percentage, without any indication of which method was used. Though it is easy to convert between wet and dry basis, confusion and potential problems occur when comparisons are made between moisture contents reported on a different basis.

In addition, moisture content reported on a dry basis can actually result in a percentage value greater than 100%, causing more confusion.

Countless methods of moisture measurement mean comparisons are nearly impossible

The AOAC lists 35different methods for measuring moisture content. These are classified as either direct or indirect measurement methods.

Direct methods involve removing the water from the product (by drying, distillation, extraction, etc.) then measuring the amount of water by weighing or titrating. Direct methods provide the most reliable results, but are usually labor intensive and time consuming. Some examples include air oven-drying, vacuum oven-drying, freeze-drying, distillation, Karl Fischer,thermogravimetric analysis, chemical desiccation, and gas chromatography.

Indirect methods do not remove the water from the sample. Instead, they involve measuring some property of the food that changes as moisture content changes. These methods require calibration to a primary or direct method. Their accuracy is limited by the accuracy of the primary method.

Indirect methods are usually fast and require little sample preparation, but are less reliable than direct measurement methods. Examples of indirect measurement methods include refractometry, IR absorption, NIR absorption, microwave adsorption, dielectric capacitance, conductivity, and ultrasonic absorption.

Further complicating the process of measuring moisture content is that one measurement method doesn’t necessarily provide the same results as another, and the measurement method isn’t often reported with the moisture content value.

Even direct measurement methods don’t provide consistent results. Any method that requires heating (i.e., loss-on drying) can cause samples to lose organic volatiles or sample decomposition – especially for samples containing high levels of sugar. For example, if organic volatiles are present in a sample or if the sample decomposes while being dried, a Karl Fischer analysis, which is not susceptible to volatile loss or decomposition, will give different results than a loss-on drying analysis.

Variability is difficult to avoid

One answer to these problems is to simply use a consistent method and only compare values that have been obtained in the same way. Unfortunately, consistency in measurement methods for moisture content analysis still will not eliminate all problems.

Consider, for instance,loss-on drying. This method seems simple enough. A sample is weighed, and the weight is recorded. The sample is then transferred to an oven, allowed to dry, and the dry weight is measured. The amount of water is determined by subtracting the dry weight from the initial weight, and the moisture content is then calculated as the amount of water divided by the dry weight or total weight, depending on the reporting method.

Even this simple loss-on-drying method is mined with potential variability traps. The most fundamental is that the term ‘dry’ has no real scientific meaning and has never been well defined. Instead, an arbitrary dryness that is reproducible has to be established for each sample.

“Dryness” is often defined as the point at which weight loss ends. However, thermogravimetric graphs show that weight loss levels off at different temperatures for different products. Also, depending on the product, the length of time needed to achieve “dryness” will differ, and a temperature that produces “dryness” in one product may cause decomposition in another.

This means that each sample has a unique ideal oven temperature and drying time. This ideal time/temperature combination is available in the literature for some products, but there are many for which it is not available. It is difficult to know which combination to use for untested products. If the same time/temperature combination is not used, the resulting moisture contents should not be compared.

Another complication is that many ovens set at one temperature can vary over time from that temperature by as much as 15 °C, and two ovens set to the same temperature can vary by as much as 40 °C.

Additional sources of variation for just the loss-on drying method include oven vapor pressure, sample preparation methods, sample particle size, sample weighing, and post-drying treatment.

It is interesting that despite the potential pitfalls, when a loss-on drying moisture content is reported in literature, it is immediately accepted as correct. In addition, when comparisons are made between moisture content methods and one of those methods is loss-on drying, it is always assumed that the loss-on drying measurement is correct.

Moisture content determination

Defining “dry” would be helpful in eliminating some of the inconsistency associated with moisture measurement.

The best way to define dry would be to identify an oven-dry water activity level. Then, the dry weight would be the weight of the sample when it has achieved this oven-dry water activity level.

Under common ambient conditions of 25 °C and 30% RH, an oven set to 95 °C would create an oven-dry water activity of 0.01 aw inside the oven, assuming that the vapor pressure in the oven is the same as the air. An oven that maintained conditions where its oven-dry water activity was always 0.01 aw, regardless of ambient conditions, would create a scientifically “dry” condition. In this type of oven, any product could be declared dry when its weight stopped changing. Its water activity would be 0.01 aw, and its weight would be the dry weight.

The vapor pressure and temperature of the oven could be adjusted to prevent release of volatiles as well, as long as the water activity in the oven was maintained at 0.01 aw. Using this method would eliminate the inconsistency that results from multiple measurement methods and an unclear definition of “dry.”

More accurate moisture analysis

Moisture content providesvaluable information about yield and quantity, making it important from a financial standpoint. It also provides information about texture, since increasing levels of moisture provide mobility and lower the glass transition temperature. However obtaining correct and consistent moisture content values can be difficult, and a moisture content measurement cannot be taken at face value without information about the methods used to generate it.

Additional problems arise when the amount of water in a product is used to tell a story it doesn’t really tell, involving product consistency, quality, or microbial safety. In these and other cases, water activity is the more accurate measurement.

For acomplete moisture analysis, food and pharmaceutical developers should measure both moisture content and water activity. In addition, moisture sorption isotherms may be used to pinpoint where optimal shelf life, texture, safety, and quality can be achieved and maintained.

Measuring moisture content (2)
Measuring moisture content (3)
Measuring moisture content (2024)

FAQs

How do you measure moisture content? ›

The amount of water is determined by subtracting the dry weight from the initial weight, and the moisture content is then calculated as the amount of water divided by the dry weight or total weight, depending on the reporting method. Even this simple loss-on-drying method is mined with potential variability traps.

How do you measure moisture content of a drug? ›

How can I measure the moisture content in pharmaceuticals? The standard method for measuring moisture in pharmaceuticals is loss on drying using a drying oven and a laboratory balance. However, this is a time-consuming and labor-intensive process.

What is the acceptable moisture level in hardwood floors? ›

What is an acceptable moisture reading in hardwood floors? Wood flooring installers typically want the moisture content of hardwood floorboards to be between 6% and 9%. That range is based on an indoor temperature of 60–80° F and 30–50% relative humidity.

What is the acceptable moisture level in a subfloor? ›

This should be stuck into your wooden subfloor. A dry reading will be 16% MC (Moisture Content) or below. With a concrete subfloor you should use a digital hygrometer, which needs to be left in place for at least 24 hours. The reading should be no more than 65% RH (Relative Humidity).

What is the moisture content formula? ›

Calculate the moisture content of the soil by subtracting the weight of the dry soil from the weight of the moist soil, and then dividing by the weight of the dry soil. Although the measurement is simple, it is important to determine soil moisture content in order to better understand soil characteristics.

What tool measures moisture content? ›

A moisture meter is an essential instrument used in many industries to detect moisture content in materials. Home and building inspectors rely on moisture meters to identify potential problems and damage to structures from moisture buildup.

How do you calculate overall moisture content? ›

Subtract the dry weight from the wet weight. Divide this number by the wet weight. Multiply by 100 to get percent moisture.

What is the unit of measurement for moisture content? ›

Common measurement units are dewpoint (°F or °C), grams of water per cubic meter of air (g/m³) or pounds of water per million cubic feet (lb/ft³).

How to check the moisture content of wood without a meter? ›

The oven-dry method. The oven-dry method involves drying a small sample of wood. The difference between the weight of the wood before drying and the weight after drying is used to determine the moisture content of the wood.

What is an acceptable moisture reading? ›

The general rule is that any moisture reading over 16% is considered damp and needs attention. If your reading is over 20%, you may need to replace the drywall entirely. The walls in your home with healthy humidity levels should have a moisture reading between 12 to 15%.

At what moisture content is wood considered dry? ›

In order to be usable for a construction project, wood must be kiln or air-dried to a moisture level of 19%. But wood that is intended for indoor use— that is, wood intended to be used for woodworking— must have a moisture content level that is less than half that amount, at only 9%.

How to detect moisture under flooring? ›

You can start by using a concrete moisture meter to locate the hot spots in the subfloor. But this is only a preliminary step. Next, use a relative humidity (RH) testing system to get quantitative data. The best tools for the job are Wagner Meters' C555, a concrete moisture meter, and the Rapid RH® L6 Testing System.

What is a good moisture level for house? ›

Every home is different, but a level between 30 and 40 per cent humidity is typically ideal for keeping your home warm and comfortable in the winter, without leaving condensation on the windows. In the summer, that level can be higher, between 50 and 60 per cent. So, how do you know your levels?

Does plywood subfloor need moisture barrier? ›

A moisture barrier should be used when installing vinyl plank flooring on top of concrete. If it's being installed on a plywood subfloor or existing flooring, this step can generally be skipped.

What instrument is used to measure moisture content? ›

A capacitive/non-destructive moisture meter measures changes in the material's capacitance which vary with the moisture content. The instrument emits a high frequency signal. The frequency of the electrical signal will vary due to the capacitance of the material.

Top Articles
Latest Posts
Article information

Author: Madonna Wisozk

Last Updated:

Views: 6238

Rating: 4.8 / 5 (48 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Madonna Wisozk

Birthday: 2001-02-23

Address: 656 Gerhold Summit, Sidneyberg, FL 78179-2512

Phone: +6742282696652

Job: Customer Banking Liaison

Hobby: Flower arranging, Yo-yoing, Tai chi, Rowing, Macrame, Urban exploration, Knife making

Introduction: My name is Madonna Wisozk, I am a attractive, healthy, thoughtful, faithful, open, vivacious, zany person who loves writing and wants to share my knowledge and understanding with you.